Lancer 115V 9W CW Condenser Fan Motor - 91-0093-SP
HomeStore

Lancer 115V 9W CW Condenser Fan Motor - 91-0093-SP

Lancer 115V 9W CW Condenser Fan Motor - 91-0093-SP

The Lancer Motor AC SP UB 115/60 0.53A 9W 1550 CW is a precision electrical drive unit responsible for pulling ambient air through the refrigeration condenser. Featuring a 1550 RPM Clockwise (CW) rotation, it dissipates heat from the compressed refrigerant, ensuring the unit builds a consistent ice bank in the water bath.

Problem Solved: Restores essential thermal management and prevents compressor burnout. Replaces failed fan motors that cause the refrigeration deck to trip on thermal overload, resulting in warm beverages.

Symptoms of Failure: Fan failing to turn, loud humming from the refrigeration deck without air movement, or the dispenser frame becoming hot to the touch during the cooling cycle.

Technician’s Note: Ensure the fan blade is not bent or obstructed before installation. An unbalanced blade creates vibration that will destroy the new motor's bearings in weeks. Clean the condenser fins of dust during every motor swap to maximize cooling performance.
Technical Specifications:
  • Voltage: 115V / 60Hz
  • Current/Power: 0.53A / 9W
  • Speed: 1550 RPM
  • Rotation: CW (Clockwise)
$19.82

Original: $56.62

-65%
Lancer 115V 9W CW Condenser Fan Motor - 91-0093-SP

$56.62

$19.82

Lancer 115V 9W CW Condenser Fan Motor - 91-0093-SP

The Lancer Motor AC SP UB 115/60 0.53A 9W 1550 CW is a precision electrical drive unit responsible for pulling ambient air through the refrigeration condenser. Featuring a 1550 RPM Clockwise (CW) rotation, it dissipates heat from the compressed refrigerant, ensuring the unit builds a consistent ice bank in the water bath.

Problem Solved: Restores essential thermal management and prevents compressor burnout. Replaces failed fan motors that cause the refrigeration deck to trip on thermal overload, resulting in warm beverages.

Symptoms of Failure: Fan failing to turn, loud humming from the refrigeration deck without air movement, or the dispenser frame becoming hot to the touch during the cooling cycle.

Technician’s Note: Ensure the fan blade is not bent or obstructed before installation. An unbalanced blade creates vibration that will destroy the new motor's bearings in weeks. Clean the condenser fins of dust during every motor swap to maximize cooling performance.
Technical Specifications:
  • Voltage: 115V / 60Hz
  • Current/Power: 0.53A / 9W
  • Speed: 1550 RPM
  • Rotation: CW (Clockwise)

Product Information

Shipping & Returns

Description

The Lancer Motor AC SP UB 115/60 0.53A 9W 1550 CW is a precision electrical drive unit responsible for pulling ambient air through the refrigeration condenser. Featuring a 1550 RPM Clockwise (CW) rotation, it dissipates heat from the compressed refrigerant, ensuring the unit builds a consistent ice bank in the water bath.

Problem Solved: Restores essential thermal management and prevents compressor burnout. Replaces failed fan motors that cause the refrigeration deck to trip on thermal overload, resulting in warm beverages.

Symptoms of Failure: Fan failing to turn, loud humming from the refrigeration deck without air movement, or the dispenser frame becoming hot to the touch during the cooling cycle.

Technician’s Note: Ensure the fan blade is not bent or obstructed before installation. An unbalanced blade creates vibration that will destroy the new motor's bearings in weeks. Clean the condenser fins of dust during every motor swap to maximize cooling performance.
Technical Specifications:
  • Voltage: 115V / 60Hz
  • Current/Power: 0.53A / 9W
  • Speed: 1550 RPM
  • Rotation: CW (Clockwise)