Lancer 115V Agitator Motor Assembly - 91-0084-SP
HomeStore

Lancer 115V Agitator Motor Assembly - 91-0084-SP

Lancer 115V Agitator Motor Assembly - 91-0084-SP

The Lancer 115V Motor AC SP UB 115V/60Hz 1.1A 25W 1500 CCW SD 8IN is the electrical drive component responsible for mechanical agitation in the water bath or driving the ice delivery auger. It is built with high-torque windings to overcome the resistance of a full ice bin or chilled water bath.

Problem Solved: Restores circulation to prevent ice bank 'bridging' or enables the consistent mechanical delivery of ice cubes to the chute. Fixes 'No Ice' conditions.

Symptoms of Failure: A loud humming noise from the unit top, warm drinks at the tap, or the ice auger failing to rotate despite power being present.

Technician’s Note: Ensure the propeller or auger is not bound by debris before replacing the motor. Stalled mechanical load is the primary cause of motor winding burnout. Verify the start capacitor is within spec.Technical Specifications:
  • Voltage: 115V / 60Hz
  • Current/Power: 1.1A / 25W
  • Rotation: CCW (Counter-Clockwise)
  • Shaft Design: 8IN Specialty Drive
$105.67
Lancer 115V Agitator Motor Assembly - 91-0084-SP
$105.67

Lancer 115V Agitator Motor Assembly - 91-0084-SP

The Lancer 115V Motor AC SP UB 115V/60Hz 1.1A 25W 1500 CCW SD 8IN is the electrical drive component responsible for mechanical agitation in the water bath or driving the ice delivery auger. It is built with high-torque windings to overcome the resistance of a full ice bin or chilled water bath.

Problem Solved: Restores circulation to prevent ice bank 'bridging' or enables the consistent mechanical delivery of ice cubes to the chute. Fixes 'No Ice' conditions.

Symptoms of Failure: A loud humming noise from the unit top, warm drinks at the tap, or the ice auger failing to rotate despite power being present.

Technician’s Note: Ensure the propeller or auger is not bound by debris before replacing the motor. Stalled mechanical load is the primary cause of motor winding burnout. Verify the start capacitor is within spec.Technical Specifications:
  • Voltage: 115V / 60Hz
  • Current/Power: 1.1A / 25W
  • Rotation: CCW (Counter-Clockwise)
  • Shaft Design: 8IN Specialty Drive

Product Information

Shipping & Returns

Description

The Lancer 115V Motor AC SP UB 115V/60Hz 1.1A 25W 1500 CCW SD 8IN is the electrical drive component responsible for mechanical agitation in the water bath or driving the ice delivery auger. It is built with high-torque windings to overcome the resistance of a full ice bin or chilled water bath.

Problem Solved: Restores circulation to prevent ice bank 'bridging' or enables the consistent mechanical delivery of ice cubes to the chute. Fixes 'No Ice' conditions.

Symptoms of Failure: A loud humming noise from the unit top, warm drinks at the tap, or the ice auger failing to rotate despite power being present.

Technician’s Note: Ensure the propeller or auger is not bound by debris before replacing the motor. Stalled mechanical load is the primary cause of motor winding burnout. Verify the start capacitor is within spec.Technical Specifications:
  • Voltage: 115V / 60Hz
  • Current/Power: 1.1A / 25W
  • Rotation: CCW (Counter-Clockwise)
  • Shaft Design: 8IN Specialty Drive