Lancer 115V Fan Motor Assembly for CED500/1500 - 52-1369-SP
The Lancer 115V Motor Assembly Fan is the primary cooling unit for the refrigeration condenser. Operating on a 115V circuit, it pulls cool ambient air through the condenser coils to dissipate heat from the compressed refrigerant, ensuring the refrigeration deck remains efficient.
Problem Solved: Restores essential thermal management. Replaces failed motors that cause the compressor to trip on thermal overload, resulting in warm beverages and potential refrigeration deck burnout.
Symptoms of Failure: Fan failing to turn, loud humming from the deck without air movement, or beverages served warm despite the compressor and agitator running.
- Voltage: 115V
- Application: Condenser Cooling
- Compatibility: Lancer CED500 and 1500 Series
- Refrigerant Compatibility: R-134A / R-290
Lancer 115V Fan Motor Assembly for CED500/1500 - 52-1369-SP
The Lancer 115V Motor Assembly Fan is the primary cooling unit for the refrigeration condenser. Operating on a 115V circuit, it pulls cool ambient air through the condenser coils to dissipate heat from the compressed refrigerant, ensuring the refrigeration deck remains efficient.
Problem Solved: Restores essential thermal management. Replaces failed motors that cause the compressor to trip on thermal overload, resulting in warm beverages and potential refrigeration deck burnout.
Symptoms of Failure: Fan failing to turn, loud humming from the deck without air movement, or beverages served warm despite the compressor and agitator running.
- Voltage: 115V
- Application: Condenser Cooling
- Compatibility: Lancer CED500 and 1500 Series
- Refrigerant Compatibility: R-134A / R-290
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Lancer 115V Motor Assembly Fan is the primary cooling unit for the refrigeration condenser. Operating on a 115V circuit, it pulls cool ambient air through the condenser coils to dissipate heat from the compressed refrigerant, ensuring the refrigeration deck remains efficient.
Problem Solved: Restores essential thermal management. Replaces failed motors that cause the compressor to trip on thermal overload, resulting in warm beverages and potential refrigeration deck burnout.
Symptoms of Failure: Fan failing to turn, loud humming from the deck without air movement, or beverages served warm despite the compressor and agitator running.
- Voltage: 115V
- Application: Condenser Cooling
- Compatibility: Lancer CED500 and 1500 Series
- Refrigerant Compatibility: R-134A / R-290